UNDER REINFORCED SECTION:
In this section, the quantity of steel is not adequate to
make the extreme concrete fibers in the compression area to get compressed to
their highest permissible stress.
In this section, the quantity of steel is not adequate to
make the concrete to get compressed in compression area to their highest
permissible value. That means the steel is provided less than that a balanced
section is required. In under reinforced section, the depth of actual Na is
less than the critical Na.
i.e; Na<Nc
BALANCED
SECTION:
The section in which the quantity of steel is just
sufficiently provided that the concrete in compression zone and steel in
tension zone reaches to their permissible stresses simultaneously is called
balanced section.
In this section, the critical depth is equal to its actual
depth.
i.e n = Na = Nc
OVER
REINFORCED SECTION:
In this section, the quantity of steel in tension zone is
greater than the quantity of steel required to make compressive zone concrete
to get compressed to their most extreme admissible value. In other words, when
the extreme compressive stress in concrete achieves its allowable limit, the
comparing tensile stress in steel will be not as much as its permissible value.
So in over reinforced section, the depth of actual Na is
greater than the critical Na.
i.e; Na > Nc